Home > Error Codes > Backplane Com Error

Backplane Com Error

Contents

See the Troubleshoot C6KPWR-4-POWRDENIED: insufficient power, module in slot [dec] power denied or %C6KPWR-SP-4-POWRDENIED: insufficient power, module in slot [dec] power denied Error Messages section of this document. Reply 0 Kudos Options Bookmark Highlight Print Email to a Friend Report Inappropriate Content DOMINIC_WYSS Re: FAS3220 Dual Chassis HA interconnect error ‎2014-08-17 01:16 AM I cable the c0a on the Troubleshoot to eliminate the possibility of a faulty module. Note:You must set the diagnostic level at complete so that the switch can perform a full suite of tests in order to identify any hardware failure.

You can also issue the errdisable recovery cause cause enable command in order to set up timeout mechanisms that automatically reenable the port after a configured timer period. In this case, the second Supervisor Engine fails to come on line because the redundancy mode is enhanced high system availability (EHSA), by default. Join over 733,556 other people just like you! A replacement hard disk drive does not rebuild.

1756-cnb Error Codes

tpa_data_6513_01#show module Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-S2U-MSFC2 SAD0628035C 2 0 Supervisor-Other unknown unknown 3 16 Pure TestLoopback : Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ---------------------------------------------------- . . . . . . . . . . . Switch-sp#sh boot BOOT variable = bootdisk:s72033-advipservicesk9_wan-mz.122-18.SXF7.bin,1; CONFIG_FILE variable does not exist BOOTLDR variable does not exist Configuration register is 0x2101 This causes the switch to boot the previous image regardless of

IBM Network Stations can have one of these messages: NSB83619--Address resolution failed NSB83589--Failed to boot after 1 attempt NSB70519--Failed to connect to a server Common Reasons/Solutions Interface delay can result in Sun Aug 17 22:00:04 GMT [N6220-SAS:cf.takeover.disabled:warning]: Controller Failover is licensed but takeover of partner is disabled. Troubleshoot CatOS to Cisco IOS Software or Cisco IOS Software to CatOS Conversion Problem when User Attempts to Access the NVRAM After Cisco IOS to CatOS Conversion Unable to Boot with Controlnet Troubleshooting Guide Reseat the module in order to resolve the problem.

For more information, refer to IOS Catalyst 6500/6000 Resets with Error "System returned to ROM by power-on (SP by abort)". Controlnet Error Codes Sun Aug 17 04:00:04 GMT [N6220-SAS:cf.ic.hourlyBackplaneLinkDownTime:error]: Backplane Interconnect link has been down for 2981 minutes Sun Aug 17 04:35:21 GMT [N6220-SAS:raid.rg.scrub.done:notice]: /aggr0/plex0/rg2: scrub completed in 3:35:17.00 Sun Aug 17 04:35:21 GMT Consider a move to Ethernet modules that do not have oversubscribed ports. Power up the chassis and make sure that the Supervisor Engine comes up without any failure.

Reply 0 Kudos Options Bookmark Highlight Print Email to a Friend Report Inappropriate Content unitech89e9 Re: FAS3220 Dual Chassis HA interconnect error ‎2014-08-17 10:35 PM N6220-SAS> sysconfig -a Data ONTAP Release Code 16#0304 Staff Online Now Cookiegal Administrator flavallee Trusted Advisor Macboatmaster Trusted Advisor Advertisement Tech Support Guy Home Forums > Software & Hardware > Hardware > Home Forums Forums Quick Links Search Forums Short URL to this thread: https://techguy.org/213296 Log in with Facebook Log in with Twitter Log in with Google Your name or email address: Do you already have an account? Please check the status of the following modules: 8,9 Module 2 had a MINOR_ERROR.

  1. resetting module Common Cause/Solution 1 When the management interface of the switch processes heavy traffic, switch logs InbandKeepAliveFailure error messages appear.
  2. Common Reasons/Solutions Console in to the standby Supervisor Engine in order to determine if it is in ROMmon mode or in continuous reboot.
  3. The amber status LED is lit.
  4. IOM6 A: 0162 IOM6 B: 0162 slot 0: SAS Host Adapter 0b (PMC-Sierra PM8001 rev.
  5. On a card with individual interface buffers, the packets that exceed the bandwidth of the destination port are silently dropped and no other ports are affected.
  6. Troubleshoot Interface Errors If you see errors in the show interface command output, check the state and health of the interface that encounters the problems.
  7. You can determine that a module does not come on line in one of these ways: The output of the show module command shows one of these statuses: other unknown faulty
  8. If you still receive messages that indicate that the Supervisor Engine is faulty, reboot the switch without that module.
  9. Kflame210 replied Oct 1, 2016 at 6:19 PM Photoimpact X3 keeps crashing...
  10. You must console in to the standby Supervisor Engine in order to recover it.

Controlnet Error Codes

Many Thanks, Julie Cancel Page 1 of 1 Related Apollo Com Spec 2 I need to control 16 Apollo com spec 2 color faders for a dance concert using... See Parts listing, IBM System x3550 M3 Type 4254 and 7944 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). 1756-cnb Error Codes If the amber hard disk drive LED and the RAID adapter software do not indicate the same status for the drive, complete the following steps: Turn off the server. 1756-cnb/e Error Codes In this case, move the oversubscribing server to port 9 in order to free up the buffer in the first block of ports 1-8.

The command does not impact switch functionality, and you can use it on a production network environment. Channeling—Channeling mode is "on" or if a port is not channeling and the mode is set to desirable. Sun Aug 17 21:49:09 GMT [N6220-SAS:shelf.config.spha:info]: System is using single path HA attached storage only. Note:RPR+ mode is available in Cisco IOS Software Release 12.1[11]EX and later. 1756 Cnb User Manual

Disable head of line blocking (HOL) which utilizes the interface buffers instead of the shared buffers. This synchronization failure can be identified by this error message: %PFINIT-SP-1-CONFIG_SYNC_FAIL_RETRY: Sync'ing the startup configuration to the standby Router FAILED, the file may be already locked by a command Even After Sun Aug 17 21:48:54 GMT [N6220-SAS:mlm.array.portEmpty.switch:info]: Fibre Channel host bus adapter 0c reports no LUNs presented by storage array IBM_2145_?, target port WWNN: 5005076803004110 WWPN: 5005076803044110, switch:port IBM_2498_B24:0. If the Supervisor Engine is in one of these states, refer to Recovering a Catalyst 6500/6000 Running Cisco IOS System Software from a Corrupted or Missing Boot Loader Image or ROMmon

c0a goes to c0a on the other head, not to c0b!you get these link states (one interconnect up, the other down) when you crossed them out.btw: if I remember correctly, it's Code 16#0204 Connection Request Error If power-on diagnostics return failure, which the F indicates in the test results, perform these steps: Reseat the module firmly and make sure that the screws are tightly screwed. For an overview of the system error messages, refer to System Messages Overview.

If the status indicates OK, as the sample output in Step 3 shows, issue the show environment alarms command in order to check for an environment alarm.

TestDontLearn : U 4 . TestL3VlanMet : . 14. This data consumes bandwidth in the 1-Gigabit Ethernet link. 1756-cn2 Make sure that the crashinfo that you view is of the most recent crash.

Via the console to the standby Supervisor Engine, observe the boot sequence in order to identify any hardware failures. In most scenarios, shared buffers do not result in any problems. The show startup-config also fails with an error code 89. This problem remains if it monitors certain VLANs and if a large number or ports is assigned to any of these VLANs.

Sun Aug 17 21:59:00 GMT [N6220-SAS:monitor.globalStatus.critical:CRITICAL]: Controller failover partner unknown. The issue may be local to this module or may be triggered by some other faulty module in the chassis. Also, refer to Field Notice: Diagnostics Incorrectly Enabled in Cisco IOS Software Release 12.1(8b)EX2 and 12.1(8b)EX3 for more information.